Spesifikasies
Tik | D09 | D12 | D18 | D25 | D32 | D40 | D50 | D65 | |
Gegradeerde werkstroom (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 |
AC1 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | |
AC-3 vlak AC3-kapasiteit van fase 3-eekhoringhokmotor AC3(KW) | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 |
380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |
415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | |
500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | |
5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | ||
Gegradeerde hittestroom (A) 660/690V | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | |
Elektriese lewe | AC3X10, | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 |
AC4X101 | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | |
Meeh anical lifeXW | 100 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | |
Nommer van die kontakte | 3P+NEE | 3P+NEE+NC |
Dimensie & Montage Grootte
vir CJX2-D09-95-kontaktors
Standaard beheerkringspannings
Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 | 500 | 660 |
50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 | Q5 | V5 | N5 | R5 | S5 | Y5 |
60Hz | B6 | D6 | E6 | F6 | M6 | P6 | U6 | Q6 | V6 | N6 | R6 | S6 | Y6 |
50/60HZ | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 | S7 | Y7 |
Spesifikasies
D80 | D95 | D115 | D150 | D170 | D205 | D245 | D300 | D410 | D475 | D620 |
80 | 95 | 115 | 150 | 170 | 205 | 245 | 300 | 410 | 475 | 620 |
37 | 44 | 52 | 60 | 75 | 85 | 105 | 117 | 138 | 147 | 180 |
22 | 25 | 30 | 40 | 55 | 63 | 75 | 100 | 110 | 147 | 200 |
37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 220 | 265 | 335 |
45 | 45 | 59 | 80 | 100 | 110 | 132 | 180 | 220 | 280 | 375 |
55 | 55 | 75 | 90 | 110 | 129 | 160 | 200 | 250 | 355 | 400 |
45 | 55 | 80 | 100 | 110 | 129 | 160 | 220 | 280 | 355 | 450 |
125 | 125 | 200 | 250 | 250 | 275 | 315 | 400 | 500 | 700 | 1000 |
60 | 60 | 200 | 60 | 60 | 50 | 50 | 50 | 30 | 30 | 20 |
10 | 10 | 15 | 15 | 15 | 15 | 15 | 15 | 8 | 8 | 5 |
600 | 600 | 300 | 300 | 300 | 300 | 300 | 300 | 100 | 100 | 100 |
3P+NC+NO |
Spesifikasies
Tik | CJX2-D115 | CJX2-D150 | ||
Gegradeerde stroom AC3 Ue< 440V | A | 115 | 150 | |
Gegradeerde verhittingstroom Ac 10 w40°C | A | 200 | 250 | |
Nominale krag Ac3 Drie-fase motor OwAuxiliary kontaktor blok (aanbeveel om te gebruik) | 220/240V | KW | 30 | 40 |
380/400V | KW | 55 | 75 | |
400V | KW | 59 | 80 | |
500V | KW | 75 | 90 | |
600/690V | KW | 80 | 100 | |
1000V | KW | 75 | 90 | |
Gegradeerde krag Ac4 Drie-fase motor 0<40 | 200/230V | KW | 9 | 11 |
380V/400V | KW | 18.5 | 22 | |
440V | KW | 18.5 | 22 | |
500V | KW | 30 | 37 | |
Gewig | Kg | 2,25 | 2,25 | |
VolumeLxBxH | mm3 | 132 x 120 x 158 | 132 x 120 x 158 | |
Gedeelte van kragverbindingsdraad | mm2 | 120 | 120 | |
Afbetaling Bott HXL-ø Geleidingspoor Aantal leispoor Xbreedte van spoor X Spoormiddelafstand | mm | 130x(95-110)-6,5 2 x 35 x 100 | 130x(95-110)-6,5 2 x 35 x 100 | |
Verwysingsmodel | LC1-D115 | LC1-D150 | ||
Beheer stroombaanspanning | AC 50HZ | V | 24(B5) 42(D5) 48(E5) | |
AC 60HZ | V | 24(B6) 42(D6) 48(E6) | ||
AC 50/60HZ | V | 24(B7) 42(D7) 48(E7) | ||
DC | V | 24(BD) 48(ED) 60(ND) | ||
Hulpkontaktorblok (aanbeveel om te gebruik) | Hulp-oombliklike kontaktorblok, kontaktor 1 LA1-DN10C LA1-DN01C | Hulp oombliklik kontaktor blok.Kontaknemer H LA1-DN11C LA1-DN20C LA1-DN02C | ||
Omkeerbare kontaktor Termiese oorlading Stuwing inhiberende module
Voeg 2 oombliklike kontakstelle ekstra by Verhoog nie die hoogte van die kabinet nie、Ander modules kan aan die voorkant van die beheeraflos bygevoeg word Van toepassing op die kontaktor en beheeraflos onder D170. . | ||||